HIGH · CVSS 7.3 Published: 2025-09-13

CVE-2025-10359 — Technical Security Advisory & CVSS Profile

A vulnerability was detected in Wavlink WL-WN578W2 221110. This impacts the function sub_404DBC of the file /cgi-bin/wireless.cgi. The manipulation of the argument macAddr results in os command injection. The attack can be launched remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Technical Metadata

IdentifierCVE-2025-10359
Base Severity / ScoreHIGH (7.3 / 10.0)
CVSS VectorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Weakness ClassificationCWE-77, CWE-78
Archive CategoriesHIGH Advisories · 2025 Index

Operational Mitigation Guidance

Prioritize remediation in the next maintenance cycle. Validate affected dependency versions in SBOM manifests and review inbound access controls. For architectural isolation principles, review per-process namespace isolation.

Upstream References

Related Security Advisories