CRITICAL · CVSS 9.8 Published: 2025-12-02
CVE-2025-11784 — Technical Security Advisory & CVSS Profile
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
Technical Metadata
| Identifier | CVE-2025-11784 |
|---|---|
| Base Severity / Score | CRITICAL (9.8 / 10.0) |
| CVSS Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| Weakness Classification | CWE-121 |
| Archive Categories | CRITICAL Advisories · 2025 Index |
Operational Mitigation Guidance
Immediate patching or compensating network isolation is strongly advised. Audit perimeter exposure, apply vendor security updates immediately, and restrict service privileges using least-privilege namespaces. For architectural isolation principles, review per-process namespace isolation.
Upstream References
Related Security Advisories
CVE-2025-11783 CRITICAL 9.8
CVE-2025-11785 CRITICAL 9.8
CVE-2025-11782 CRITICAL 9.8
CVE-2025-11786 CRITICAL 9.8
CVE-2025-11788 CRITICAL 9.8
CVE-2025-11832 CRITICAL 9.8