CVE-2025-12679 — Technical Security Advisory & CVSS Profile
A vulnerability in Brocade SANnav before 2.4.0b prints the Password-Based Encryption (PBE) key in plaintext in the system audit log file. The vulnerability could allow a remote authenticated attacker with access to the audit logs to access the pbe key. Note: The vulnerability is only triggered during a migration and not in a new installation. The system audit logs are accessible only to a privileged user on the server. These audit logs are the local server VM’s audit logs and are not controlled by SANnav. These logs are only visible to the server admin of the host server and are not visible to the SANnav admin or any SANnav user.
Technical Metadata
| Identifier | CVE-2025-12679 |
|---|---|
| Base Severity / Score | MEDIUM (6.5 / 10.0) |
| CVSS Vector | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N |
| Weakness Classification | CWE-312 |
| Archive Categories | MEDIUM Advisories · 2026 Index |
Operational Mitigation Guidance
Schedule vendor updates during routine patching windows and verify whether affected code paths are reachable in your deployment configuration. For architectural isolation principles, review per-process namespace isolation.