MEDIUM · CVSS 5.2 Published: 2025-07-08
CVE-2025-24004 — Technical Security Advisory & CVSS Profile
A physical attacker with access to the device display via USB-C can send a message to the device which triggers an unsecure copy to a buffer resulting in loss of integrity and a temporary denial-of-service for the stations until they got restarted by the watchdog.
Technical Metadata
| Identifier | CVE-2025-24004 |
|---|---|
| Base Severity / Score | MEDIUM (5.2 / 10.0) |
| CVSS Vector | CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L |
| Weakness Classification | CWE-120 |
| Archive Categories | MEDIUM Advisories · 2025 Index |
Operational Mitigation Guidance
Schedule vendor updates during routine patching windows and verify whether affected code paths are reachable in your deployment configuration. For architectural isolation principles, review per-process namespace isolation.
Upstream References
Related Security Advisories
CVE-2025-24003 HIGH 8.2
CVE-2025-24005 HIGH 7.8
CVE-2025-24002 MEDIUM 5.3
CVE-2025-24010 MEDIUM 6.5
CVE-2025-24011 MEDIUM 5.3
CVE-2025-24012 MEDIUM 4.6
CVE-2025-24013 MEDIUM 5.3
CVE-2025-24014 MEDIUM 4.2